当前位置 : 首页 > 市场合作 > 项目信息市场合作
Market cooperation| 发包方名称 | National University Corporation - Ibaraki |
| 发包方国别(国家/地区) | 日本 |
| 发包方座机 | 029-853-2176 |
| 发包方传真 | |
| 发包方邮箱 | |
| 发包方地址 | Division of Contracts, Department of Finance and Accounting, University of Tsukuba, 1-1-1 Tennodai Tsukuba-shi 305-8577 Japan, |
| 发包方网址 | |
| 发包方联系人姓名 | |
| 发包方联系人座机 | |
| 发包方联系人手机 | |
| 发包方联系人邮箱 | |
| 项目名称 | Campus Information Network System 1 Set |
| 项目类型 | 其他 - 其他 |
| 项目预算¥ | |
| 项目投标截止时间 | 2022-09-09 |
| 项目开始时间 | |
| 项目结束时间 | |
| 服务商资质要求 | |
| 要求高匹配度成功案例个数 | |
| 项目交付地点 | |
| 是否准许转包或分包 | |
| 项目信息详述 |
⑴ Classification of the products to be procured : 15, 28
⑵ Nature and quantity of the products to be purchased : Campus Information Network System 1 Set
⑶ Type of the procurement : Rent
⑷ Basic requirements of the procurement :
A The system must be a high-speed network system covering from the backbone network to terminals within University of Tsukuba and all the related facilities.
B The core equipment of the system must provide various levels of redundancy as much as possible to raise the reliability of the network system.
C To ensure security, the system must be equipped with functions to cope with various and latest network attacks.
D The bandwidth of the information outlets of the terminals must be 1Gbps or more. In consideration of the use on the researches which need large-bandwidth, part of the information outlets must have additional care to offer 2.5Gbps or 10Gbps.
E The connection between each floor switch and core switches that aggregate the upstream s of the floor switch must be redundant and have a bandwidth of 10Gbps+10Gbps or more via more than one . It is preferable that the core switches are able to aggregate upstream s of 40Gbps or 100Gbps from on-campus systems.
F In order to prevent the information outlets from fraudulent terminal connection, this system must have a function that can control network access privileges for each terminal.
G The system must be fully labor-saving and automated in its operation and management.
H The system must be provided with a mature level of technical support that offers prompt and correct responses in case of system renewal and system failure.
I The system must promote energy-saving, space-saving, and noise-reducing.
⑸ Time limit for the submission of the requested material : 17 : 00 9 September, 2022
⑹ Contact point for the notice : Takuya Kobayashi, Division of Contracts, Department of Finance and Accounting, University of Tsukuba, 1-1-1 Tennodai Tsukuba-shi 305-8577 Japan, TEL 029-853-2176
|
版权所有:天津市数字贸易综合服务平台 备案号:津B2-20080229-9